home products operation existing installations future developments contact us
previous
HID Range
Lamp Power
Controller
Main Ballast
Injector
150W
AR 150 HPS
OMS100
OMS70A-21
250W
AR 250 HPS
OGS150-108(*)
OMS70A-21(*)
400W
AR 400 HPS
OGS250-04(*)
OMS70(*)
NOTES
1
All ballasts and injectors are TridonicAtco series reactor type (except 2000 W)
2
(*) denotes standard Tridonic Atco ballast with reduced turns
3
Initial lamp power for HPS is set to 75% (nominal) of rated lamp power
Initial lamp power for MH is set to 80% (nominal) of rated lamp power

Data Sheet

400W High Pressure Sodium Lamp on Active Reactor Controller
Components
Active Reactor 400W HPS
Main Ballast  Tridonic.Atco OGS250
Injector   Tridonic.Atco OMS70
Ignitor Tridonic.Atco AZRM6ES
Lamp 400 W high pressure sodium
Results (for new lamp)
Supply Voltage 240 V, 50 Hz
Lamp Power 300 W (75% rated power)
Lamp Voltage 84 V
Lamp Current 4.3 A
Lamp Flux Approx 72% rated flux
THD Current 10%
Regulation  +/- 10% supply voltage variation (216V – 264V)
Ballast losses Approx 30 W
previous

Circuit Diagram

Active Reactor Legend
MB
Main Ballast
CB
Control Ballast (Current Injector)
SW
Electronically Program Controlled Triac Switch
PCB
Active Reactor Printed Circuit Board

previous